Solar Panel Output Calculator

Estimate the kWh your solar panels produce per day, month and year from system size, location, tilt, direction and losses.

System size as
kW
panels
W
Most new home panels are rated 350 to 450 W.
°
Roof pitch 4/12 is about 18°, 6/12 is 27°, 12/12 is 45°. Flat is 0°.
%
PVGIS default is 14% for wiring, inverter, soiling and ageing.

Formula used

Formula and method below. Last checked by the SolarCalcLab Editorial Team.

Quick answer

Solar output equals system size times specific yield, the yearly kWh that 1 kW of panels makes at your site, tilt and direction. E = kW × yield. A 6 kW system on a 20° south-facing roof in Phoenix yields about 1,789 kWh per kW, so it produces about 10,735 kWh a year, or 29.4 kWh a day.

SolarCalcLab solar panel output calculator showing 10,735 kWh/year for the default example
The Solar Panel Output calculator with a worked example. Change any input and the result updates instantly.

How to use the solar panel output calculator

  1. Choose how to enter system size. Pick Total kW if you know the system rating. Pick Panels × watts to enter the number of panels and the wattage of each one.
    Step 1: choose how to enter system size in the Solar Panel Output calculator
  2. Enter the system size. Use the DC rating of the panels, such as 6 kW. This is the sum of the panel ratings, not the inverter rating.
    Step 2: enter the system size in the Solar Panel Output calculator
  3. Set your location. Search for your city or use your device location. Output is calculated from PVGIS long-term solar data for that point.
    Step 3: set your location in the Solar Panel Output calculator
  4. Enter the panel tilt. Use your roof pitch in degrees. A 4/12 roof is about 18°, 6/12 is about 27° and 12/12 is 45°. Use 0° for flat-mounted panels.
    Step 4: enter the panel tilt in the Solar Panel Output calculator
  5. Choose the direction the panels face. Toward the equator means south in the northern hemisphere and north in the southern hemisphere. East, west and in-between directions are also available.
    Step 5: choose the direction the panels face in the Solar Panel Output calculator
  6. Set the system losses. Leave 14% unless you have a reason to change it. Use a higher value for dusty sites or long cable runs, and a lower one for new, high-efficiency equipment.
    Step 6: set the system losses in the Solar Panel Output calculator
  7. Read the estimated output. The big number is yearly kWh. The cards show the daily and monthly averages and the specific yield, and the chart shows each month.
    Step 7: read the estimated output in the Solar Panel Output calculator

Solar panel output formula

Eyear = P × Y
Eday = Eyear ÷ 365, Emonth = Eyear ÷ 12
P = number of panels × panel W ÷ 1,000

Where:

PVGIS measures direction as degrees from south: 0 is south, minus 90 is east and plus 90 is west. The PVGIS user manual explains this convention and its 14% default for system losses. The calculator converts your direction choice for you.

The monthly chart uses the PVGIS output for each month, so it shows the real seasonal pattern rather than an even split.

Worked examples

Example 1: 6 kW on a 20° south roof in Phoenix

PVGIS gives a specific yield of about 1,789 kWh per kW for this roof with 14% losses.

E = 6 × 1,789 = 10,734 kWh per year

That is about 10,734 ÷ 365 = 29.4 kWh a day and 895 kWh a month on average.

Example 2: 15 panels of 400 W on an east roof in New York

System size is 15 × 400 ÷ 1,000 = 6 kW. At 20° tilt facing east, PVGIS gives about 1,140 kWh per kW in New York City.

E = 6 × 1,140 = 6,840 kWh per year

The same panels facing south at 20° would yield about 1,346 kWh per kW, or 8,076 kWh. The east roof makes about 15% less.

Example 3: 10 kW at 35° south in Berlin

PVGIS gives about 1,049 kWh per kW for this setup.

E = 10 × 1,049 = 10,490 kWh per year, or 28.7 kWh a day

In Berlin, summer months produce several times more than December, so the daily average hides a large seasonal swing.

Specific yield by tilt and direction

PVGIS 5.3 yields in kWh per kW per year with 14% losses, retrieved October 2026. Multiply by your system kW to get yearly output.

Setup Phoenix, AZ New York, NY Berlin, Germany
Flat (0°) 1,581 1,156 870
20° facing south 1,789 1,346 1,006
35° facing south 1,829 1,402 1,049
45° facing south 1,799 1,396 1,049
20° facing east 1,551 1,140 860
20° facing west 1,515 1,108 844
Vertical (90°) facing south 1,109 952 758

What affects the result

Sunshine at your location

Yield follows the solar energy that reaches the panel. In the table, a south-facing 35° array makes about 74% more per kW in Phoenix than in Berlin. Cloud, haze and latitude all play a part.

Tilt and direction

Output peaks near the tilt that PVGIS finds optimal, and the curve is flat near the top. In Phoenix, 20° to 45° south roofs land within about 2% of each other. East and west roofs lose more, about 15 to 17% at 20° in Phoenix.

System losses

The loss figure scales output almost directly. Raising losses from 14% to 20% cuts output by about 7%. Shade is not part of this figure, so a shaded roof can produce much less than the estimate.

Heat

Panels lose efficiency as they warm up. PVGIS includes temperature effects from local weather data, which is one reason hot, sunny places do not gain output in full proportion to their sunshine.

Year-to-year weather

The result is a long-term average. A cloudy year can come in several percent below it and a clear year above it, so judge a system on more than one year of data.

Frequently asked questions

How much electricity does a 6 kW solar system produce?

It depends on location and roof. Using PVGIS data, a 6 kW system at 20° facing south makes about 10,700 kWh a year in Phoenix, 8,100 kWh in New York and 6,000 kWh in Berlin. Enter your own location, tilt and direction above for a site-specific estimate.

How many kWh does a solar panel produce per day?

Divide the yearly output by 365. A 400 W panel on a 20° south roof yields about 1,789 kWh per kW per year in Phoenix, so 0.4 × 1,789 ÷ 365 = 1.96 kWh a day. Winter days produce less and summer days more than this average.

Is south always the best direction?

In the northern hemisphere, a south-facing tilt gives the most yearly energy. In the southern hemisphere, north-facing is best. West-facing panels make less in total but produce more in the late afternoon, which can be worth more on time-of-use tariffs.

What does 14% system loss include?

It covers losses between the panel rating and the power delivered: cable resistance, inverter conversion, dirt on the glass, small mismatches between panels and gradual ageing. It does not include shading from trees or buildings. PVGIS uses 14% as its default.

Why is my real output different from the estimate?

Weather varies year to year, and shade, dirt, snow or an undersized inverter can cut output. Your monitoring may also report AC energy after the inverter while a quote shows DC. Compare at least a full year of data against the yearly estimate, not a single month.

Related calculators