Peak Sun Hours Calculator

Find the average peak sun hours per day at your location, month by month, for an optimal, latitude, flat or custom panel tilt.

Panel tilt
°

Formula used

Formula and method below. Last checked by the SolarCalcLab Editorial Team.

Quick answer

Peak sun hours are the daily solar energy on a panel, counted as hours of full 1,000 W/m² sunlight. PSH = in-plane irradiation (kWh/m²) ÷ days. Phoenix gets about 2,464 kWh/m² a year on a panel at its best tilt, so it averages 6.75 peak sun hours a day. London averages about 3.5.

SolarCalcLab peak sun hours calculator showing 6.75 h/day for the default example
The Peak Sun Hours calculator with a worked example. Change any input and the result updates instantly.

How to use the peak sun hours calculator

  1. Set your location. Search for your city or use your device location. The calculator reads monthly sunlight on a tilted panel at that spot from PVGIS, the European Commission’s solar database.
    Step 1: set your location in the Peak Sun Hours calculator
  2. Choose the panel tilt. Optimal uses the tilt that gives the most yearly energy. Latitude sets the tilt equal to your latitude, Flat is 0°, and Custom lets you enter your roof pitch. For Latitude and Custom you can also choose the direction the panels face.
    Step 2: choose the panel tilt in the Peak Sun Hours calculator
  3. Read the peak sun hours. The big number is the yearly average per day. The cards show the best and lowest months and the yearly total, and the chart shows every month.
    Step 3: read the peak sun hours in the Peak Sun Hours calculator

Peak sun hours formula

One peak sun hour is one hour of sunlight at 1,000 W/m², the intensity used to rate solar panels. That equals 1 kWh/m² of energy. So peak sun hours per day are simply the day’s solar energy on the panel in kWh/m².

PSHyear = Hyear ÷ 365.25
PSHmonth = Hmonth ÷ days in the month

Where:

The calculator takes H from PVGIS 5.3. The PVGIS user manual describes how it reports monthly irradiation on a fixed plane and how it finds the optimal slope.

To turn peak sun hours into panel output, multiply by panel kW and a loss factor:

kWh per day = PSH × panel kW × 0.86

Here 0.86 allows for 14% losses in wiring, the inverter, heat and dirt.

Worked examples

Example 1: Phoenix at the optimal tilt

PVGIS gives 2,464 kWh/m² a year on a panel tilted 33° facing roughly south.

PSH = 2,464 ÷ 365.25 = 6.75 h per day

December is the lowest month at 163 kWh/m², or 163 ÷ 31 = 5.26 h per day.

Example 2: London at the optimal tilt

PVGIS gives 1,264 kWh/m² a year at about 40°.

PSH = 1,264 ÷ 365.25 = 3.46 h per day

The monthly range in London is wide: about 5.1 h in the best month and 1.4 h in the lowest.

Example 3: From peak sun hours to panel output

A 400 W panel (0.4 kW) at a site with 5 peak sun hours:

kWh per day = 5 × 0.4 × 0.86 = 1.72 kWh

Over a year that is about 1.72 × 365 = 628 kWh from one panel.

Peak sun hours by city

PVGIS 5.3 data at the optimal or near-optimal tilt facing the equator, retrieved October 2026. Best and lowest are monthly averages per day.

City Tilt Yearly average (h/day) Best month Lowest month
Phoenix, AZ 33° 6.75 7.78 5.26
Los Angeles, CA 32° 6.41 7.33 4.79
Denver, CO 40° 6.34 6.92 5.03
Miami, FL 26° 5.48 6.23 4.67
New York, NY 38° 4.82 5.59 3.29
Chicago, IL 38° 4.68 6.24 2.44
Seattle, WA 39° 4.06 6.05 1.67
London, UK 40° 3.46 5.09 1.44
Berlin, Germany 40° 3.60 5.61 1.09
Sydney, Australia 33° 5.40 6.09 3.96
Melbourne, Australia 36° 4.96 6.51 2.92
Perth, Australia 32° 5.97 7.29 4.07

What affects the result

Latitude and climate

Places closer to the equator with dry air get more peak sun hours. Cloud matters as much as latitude: Denver and Phoenix sit at different latitudes but have similar yearly averages.

Panel tilt

A tilted panel catches more sunlight than a flat one in most places. In PVGIS data for Phoenix, a flat panel receives 2,145 kWh/m² a year against 2,464 at 33°, about 13% less. Steeper tilts favor winter and flatter tilts favor summer.

Direction

Panels facing away from the equator lose sunlight, and east or west faces lose some too. Peak sun hours always refer to a specific tilt and direction, so compare figures on the same basis.

Season

Monthly figures swing far more at high latitudes. Berlin’s best month gets about five times the daily sunlight of its lowest, so an off-grid system there must be sized for winter, not the yearly average.

Frequently asked questions

What is a peak sun hour?

It is one hour of sunlight at 1,000 W per square meter, which equals 1 kWh/m². A day with 5 kWh/m² of sunlight on the panel has 5 peak sun hours, even if the sun was up for 14 hours. It is a measure of energy, not of daylight.

Are peak sun hours the same as hours of daylight?

No. Morning and evening light is weak, so a long summer day may hold only 6 or 7 peak sun hours. Peak sun hours squeeze the whole day’s energy into the equivalent hours at full 1,000 W/m² intensity, which makes them easy to use in solar sizing.

How many peak sun hours do I need for solar to be worth it?

There is no fixed cutoff. Solar pays back in places with 3 to 4 peak sun hours, such as Germany and the UK, because electricity prices there are high. Payback depends on sunshine, system cost and your electricity rate together. Use the solar payback calculator to test it.

Should I use the yearly or the lowest monthly value?

Use the yearly average for grid-tied systems, because surplus summer output offsets the winter shortfall over the year. Use the lowest month for off-grid systems that must cover every day of the year without a grid connection, since winter is when they run short.

Where does this sun data come from?

From PVGIS 5.3, a free tool run by the European Commission’s Joint Research Centre. It uses satellite-based radiation databases and reanalysis data, depending on region, and models the light on a tilted plane. Figures are long-term averages, so single years vary.

Related calculators